- Overview
- Detailed Photos
Basic Info.
Model NO.
LRM2-63 1P
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCB
Poles Number
1,2,3,4
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection, Overcurrent Protection, Short-Circuit Protection, Overload Protection
Certification
ISO9001-2000, CE, CB, CCC
Model
Lrm2-63
Rated Voltage(V)
230/400 VAC
Rated Frequency
50/60Hz
Number of Poles
1p. 2p, 3p, 4p
Ics=Icn
6000A
Transport Package
240 PCS/Carton
Specification
IEC60898-1/IEC60947-2
Trademark
Longroad/OEM
Origin
China
Production Capacity
300, 000 Poles/Month
Packaging & Delivery
Package Size
45.00cm * 23.00cm * 33.50cm
Package Gross Weight
24.000kg
Product Description
1. General
1.1 Function
protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation,
The LRM2-63 circuit-breakers are used in domestic installation as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered: the earthing systems (TNS, TNC), short-circuit current at the circuit-breaker installation point , which must always be less than the breaking capacity of this device, network normal voltage.
Tripping curves:
B curve (3-5In):protection for people and big length cables in TN and IT systems.
C curve (5-10In):protection for resistive and inductive loads with low inrush current.
D curve(10-14In) :protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps)
2.Technical parameter
2.Technical parameter
Model | LRM2-63 |
No. Of Poles | 1P, 2P, 3P, 4P |
Rated Current (In):(A) | 1A,2A,3A,6A,10A,16A,20A,25A,32A,40A,50A,63A |
Rated voltage(Un):(V) | 220V~/230V~/240V~(1P), 380V~/400V~/415V~ (2P,3P,4P); |
Rated frequency:(Hz) | 50/60Hz |
Rated Insulation voltage Ui:(V) | 415V |
Rated impulse withstand voltage(1.2/50us)Uimp:(V) | 4000V |
Rated short-circuit capacity Icn:(A) | 6000A |
Instaneous Tripping current: | B Type(3In~5In) C Type(5In~10In) D Type(10In~20In) |
Protection Degree | IP20 |
Contact position indication | Red/Green |
Ambient temperature | -5~40ºC |
Method of mounting | On 35mm Din rail |
Terminal connection type | Screw terminal, Pillar terminal with clamp |
Connection capacity: | 16mm² flexible or 25mm² rigid up to 25A ratings ,25mm² flexible or 35mm² rigid from 32A to 63A ratings |
Tightening torque | 2.5N.m |
Connection | From top and bottom |
3. Technical data:3. Overall & Installation Dimensions