Basic Info.
Packaging & Delivery
Product Description
Anaerobic Glove Box Inert Gas Displacing For Mobile Phone Batteries Lab Chemical Laboratory Research Testing Vacuum Chamber Isolator
Main Feature acrylic chamber acrylic chamber acrylic chamber acrylic chamber acrylic chamber
1.The material is clarity PMMA with high transparent, which is sample structure and easy to operate
2.Be able to pass through ultraviolet light cheap acrylic lab glove box cheap acrylic lab glove box
3.There is a porous electrical socket in the glove box,which is convenient to scientific experiments
4.Good sealing performance,and can shield and absorb the α -rays and low-energy β -rays which is emitted by radioactive materials, in case to damage on the human body by ionizing radiation
Main Application acrylic chamber acrylic chamber acrylic chamber
1.In cooperation with scientific institution in the experiment of low-energy radioactive substance, it can be worked in the operation box when aseptic operation of microorganism inoculation and qualitative and quantitative analysis of chemicals and other airtight isolation operations.
2.Electronic materials, magnetic materials, equipment batteries, biological cultivation, food packaging, battery materials, etc.processing under protective atmosphere. cheap acrylic lab glove box cheap acrylic lab glove box
3.The glove box is a laboratory facility that high purity inert gas is introduced in the box and cyclic filtration the active substances. Also known as vacuum glove box, inert gas protective box, etc.
The main function is to remove the O2 and H2O and the organic gas.Widely used in ultra-pure environment without water, oxygen and dust. For example: lithium ion batteries and materials, semiconductors, super capacitors, special lamp, laser welding, brazing, material synthesis, OLED,MOCVD,etc. Also including biological applications, such as anaerobic culture, cell hypoxia culture, etc.
Different of acrylic glove box Type-A-B-C:
Type-A: This glove box is specifically for protection against radiation, isolation operation or dust-proof operation, and no transition box.
Type-B: As an anaerobic anhydrous glove box, the transition room can be vacuumed, and the operation room is replaced by inert gas.
Type-C: Operation box and transition box can be vacuumed, limit vacuum degree can reach -0.1mpa.
Acrylic glove box -Type A | |||||||
Model | Operation box dimension(mm) | Material thickness(mm) | Transition box | Vacuum is pumped | Material | Left round door | Working Station |
MT012 | 700*450*500 | 10mm | No | No | PMMA | 300mm | Single working station |
MT011 | 800*550*600 | 10mm | No | No | PMMA | 350mm | Single working station |
MT010 | 1000*500*500 | 10mm | No | No | PMMA | 300mm | Single working station |
MT009 | 1000*700*500 | 10mm | No | No | PMMA | 300mm | Single working station |
MT008 | 900*600*700 | 10mm | No | No | PMMA | 300mm | Single working station |
MT007 | 1000*600*700 | 10mm | No | No | PMMA | 300mm | Single working station |
MT006 | 1000*750*700 | 10mm | No | No | PMMA | 300mm | Single working station |
MT005 | 1200*600*600 | 10mm | No | No | PMMA | 350mm | Double working station |
MT004 | 1200*600*700 | 10mm | No | No | PMMA | 350mm | Double working station |
MT003 | 1200*800*600 | 10mm | No | No | PMMA | 350mm | Double working station |
MT002 | 1200*800*700 | 10mm | No | No | PMMA | 350mm | Double working station |
MT001 | 1094*640*645 | 10mm | No | No | PMMA | 400mm | Double working station |
Acrylic glove box -Type B with inert gas replacement | ||||||||
Model | Operation box dimension(mm) | Acrylic thickness(mm) | Transition box | Vacuum is pumped | Material | Left round door | Gloves | |
Operation box vacuum | Transition box vacuum | |||||||
MT012 | 700*450*500 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT011 | 800*550*600 | 10mm | Yes | No | Yes | PMMA | 350mm | Two |
MT010 | 1000*500*500 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT009 | 1000*700*500 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT008 | 900*600*700 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT007 | 1000*600*700 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT006 | 1000*750*700 | 10mm | Yes | No | Yes | PMMA | 300mm | Two |
MT005 | 1200*600*600 | 10mm | Yes | No | Yes | PMMA | 350mm | Four |
MT004 | 1200*600*700 | 10mm | Yes | No | Yes | PMMA | 350mm | Four |
MT003 | 1200*800*600 | 10mm | Yes | No | Yes | PMMA | 350mm | Four |
MT002 | 1200*800*700 | 10mm | Yes | No | Yes | PMMA | 350mm | Four |
MT001 | 1094*640*645 | 10mm | Yes | No | Yes | PMMA | 400mm | Four |
Acrylic glove box -Type C with vacuum atmosphere protection | ||||||||
Model | Operation box dimension(mm) | Acrylic thickness(mm) | Transition box | Vacuum | Material | Left round door | Gloves | |
Main box vacuum | Transition box vacuum | |||||||
MT012 | 700*450*500 | 20mm | Yes | Yes | Yes | PMMA | 300mm | Two |
MT011 | 800*550*600 | 25mm | Yes | Yes | Yes | PMMA | 350mm | Two |
MT010 | 1000*500*500 | 25mm | Yes | Yes | Yes | PMMA | 300mm | Two |
MT009 | 1000*700*500 | 30mm | Yes | Yes | Yes | PMMA | 300mm | Two |
MT008 | 900*600*700 | 30mm | Yes | Yes | Yes | PMMA | 300mm | Two |
MT007 | 1000*600*700 | 30mm | Yes | Yes | Yes | PMMA | 300mm | 0Two |
MT006 | 1000*750*700 | 30mm | Yes | Yes | Yes | PMMA | 300mm | Two |
MT005 | 1200*600*600 | 30mm | Yes | Yes | Yes | |||
MT004 | 1200*600*700 | 30mm | Yes | Yes | Yes | |||
MT003 | 1200*800*600 | 30mm | Yes | Yes | Yes | |||
MT002 | 1200*800*700 | 30mm | Yes | Yes | Yes | |||
MT001 | 1094*640*645 | 30mm | Yes | Yes | Yes | PMMA | 400mm | Four |
Qualification:
Vacuum degree of transition room | 0~-0.1Mpa(2.5 level vacuum meter),Pressure maintaining over 12 hours |
Vacuum degree of transition room | 0~-0.1Mpa(2.5 level vacuum meter),pressure maintaining over 12 hours |
Using gas | Argon,Helium,Nitrogen(purity 99.95%) and more |