Overview

Basic Info.

Model NO.
MDRCCB
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
ELCB
Poles Number
2
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
CE, CB
Rated Voltage
220V-400V
Bcd Curve
C
Rated Frequency (Hz)
50/60
Rated Current
63A
Mechanical Life
20000 Times
Pole
1p/2p/3p/4p
Installation Way
DIN Standard Rail
Product Name
Residual Current Circuit Breaker RCCB
Transport Package
Carton
Trademark
MOREDAY
Origin
China
HS Code
8536200000
Production Capacity
100000PCS/Month

Packaging & Delivery

Package Size
10.00cm * 8.00cm * 5.00cm
Package Gross Weight
1.000kg

Product Description

Product Description


An RCCB (residual current circuit breaker) for an EV charger is a safety device that is specifically designed for use with electric vehicle charging systems. It is used to protect against electrical fires and shocks caused by overcurrent, short circuits, and earth leakage. The RCCB is typically installed between the EV charger and the electrical distribution panel of a home or commercial building, and is designed to automatically disconnect the charger in the event of an electrical fault. It is an important component of any EV charging system, as it helps to ensure the safety of the charger and the vehicle being charged. The RCCB is typically designed to be compatible with various types of EV chargers, including Level 1, Level 2, and Level 3 chargers.

 
Product Parameters
Standard
IEC60898-1
Poles
2P, 4P
Rated current In (A)
25, 32, 40, 50, 63
Rated voltage Un (V)
230/400V AC 50/60Hz
Rated residual currents In (mA)
10, 30, 100, 300
Rated residual non-operating current
0.5xln
Rated impulse withstand voltage Uimp
6,000V
Rated conditional short-circuit current, Inc
10kA
Installation
Installed on 35mm DIN rail
 
 
Detailed Photos

Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload ProtectionMoreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload ProtectionMoreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload ProtectionMoreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload ProtectionMoreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload ProtectionMoreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection
Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection

Certifications

Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection

Our Advantages

 

Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection
Company Profile

 

Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection
Packaging & Shipping

Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection

FAQ

1. Are you trading company or manufacturer ?
 We are solar system manufacturer,Our cumulative installed capacity reached 5GW+.

2.Can you supply samples for checking ?
 Yes, we can supply free samples for all  client.

3.How long is your delivery time?
 A1)For Sample: 1-2Days ;
 A2)For small Orders: 3-5Days;
 A3)For mass Orders:7-10Days;
 Anyway,  It depend on order qty and payment time.
 
4.Do you accept OEM business?
We accept OEM with your authorization.

5.How is the after-sale service?
We offer spare parts accordingly and English-speaking engineer offer online service. 

6. what kind of certificate you have ?
We have CE, CB,TÜV,SAA etc.

7.What is the service offered by company? 
We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale.

If you have another questions, pls feel free to contact us.
Moreday 1p+N RCBO OEM 30mA 6A 10A 16A 20A 25A 32A 40A Earth Leakage Circuit Breaker with Overload Protection

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours